Pipeline QA summary for this task.
Score Reason
0.00 VLASS2.1.sb38521729.eb38627577.59093.001901145835_split.ms is missing AMPLITUDE and PHASE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS2.1.sb38521729.eb38627577.59093.001901145835_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS2.1.sb38521729.eb38627577.59093.001901145835_split.ms uid://evla/pdbsb/38521729 MS MS 13 392 13 10.0 GiB

No flux densities were imported.

save_flagonline
True
datacolumns
{}
nocopy
True
session
session_1
vis
/mnt/condor/execute/dir_26520/rawdata/VLASS2.1.sb38521729.eb38627577.59093.001901145835_split.ms
ocorr_mode
co
process_caldevice
True
overwrite
False
lazy
False
asis
Receiver CalAtmosphere
bdfflags
False
output_dir
 
createmms
false
Start time
2024-04-30 22:25:17.477
End
2024-04-30 22:25:36.179
Duration
0:00:18.702
Note, WebLog generation is not included in the time.

CASA logs for stage 1