Pipeline QA summary for this task.
Score Reason
0.00 VLASS2.1.sb38619162.eb38631105.59096.06071193287_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS2.1.sb38619162.eb38631105.59096.06071193287_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS2.1.sb38619162.eb38631105.59096.06071193287_split.ms uid://evla/pdbsb/38619162 MS MS 11 341 11 8.3 GiB

No flux densities were imported.

ocorr_mode
co
lazy
False
process_caldevice
True
session
session_1
bdfflags
False
output_dir
 
vis
/mnt/condor/execute/dir_1608765/rawdata/VLASS2.1.sb38619162.eb38631105.59096.06071193287_split.ms
overwrite
False
save_flagonline
True
createmms
false
nocopy
True
asis
Receiver CalAtmosphere
datacolumns
{}
Start time
2024-12-12 22:01:09.143
End
2024-12-12 22:01:21.738
Duration
0:00:12.595
Note, WebLog generation is not included in the time.

CASA logs for stage 1