Pipeline QA summary for this task.
Score Reason
0.00 VLASS2.1.sb38499285.eb38509861.59047.50492306713_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS2.1.sb38499285.eb38509861.59047.50492306713_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS2.1.sb38499285.eb38509861.59047.50492306713_split.ms uid://evla/pdbsb/38499285 MS MS 11 341 11 10.1 GiB

No flux densities were imported.

lazy
False
output_dir
 
session
session_1
save_flagonline
True
bdfflags
False
vis
/mnt/condor/execute/dir_1129613/rawdata/VLASS2.1.sb38499285.eb38509861.59047.50492306713_split.ms
datacolumns
{}
ocorr_mode
co
overwrite
False
createmms
false
process_caldevice
True
nocopy
True
asis
Receiver CalAtmosphere
Start time
2024-11-06 23:07:47.256
End
2024-11-06 23:08:09.873
Duration
0:00:22.616
Note, WebLog generation is not included in the time.

CASA logs for stage 1