Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb45781633.eb46186110.60491.63280148148_split.ms is missing AMPLITUDE and PHASE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb45781633.eb46186110.60491.63280148148_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb45781633.eb46186110.60491.63280148148_split.ms uid://evla/pdbsb/45781633 MS MS 11 284 11 8.4 GiB

No flux densities were imported.

save_flagonline
True
vis
/mnt/condor/execute/dir_1396652/rawdata/VLASS3.2.sb45781633.eb46186110.60491.63280148148_split.ms
createmms
false
datacolumns
{}
overwrite
False
lazy
False
process_caldevice
True
bdfflags
False
output_dir
 
nocopy
True
ocorr_mode
co
session
session_1
asis
Receiver CalAtmosphere
Start time
2024-08-13 22:02:21.975
End
2024-08-13 22:02:43.482
Duration
0:00:21.507
Note, WebLog generation is not included in the time.

CASA logs for stage 1