Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb45524610.eb46199195.60503.373281504624_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb45524610.eb46199195.60503.373281504624_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb45524610.eb46199195.60503.373281504624_split.ms uid://evla/pdbsb/45524610 MS MS 13 380 13 9.3 GiB

No flux densities were imported.

session
session_1
overwrite
False
save_flagonline
True
nocopy
True
ocorr_mode
co
lazy
False
datacolumns
{}
output_dir
 
asis
Receiver CalAtmosphere
vis
/mnt/condor/execute/dir_1481127/rawdata/VLASS3.2.sb45524610.eb46199195.60503.373281504624_split.ms
createmms
false
bdfflags
False
process_caldevice
True
Start time
2024-07-16 17:01:29.824
End
2024-07-16 17:01:44.578
Duration
0:00:14.754
Note, WebLog generation is not included in the time.

CASA logs for stage 1