Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb46277386.eb46352893.60542.59084615741_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb46277386.eb46352893.60542.59084615741_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb46277386.eb46352893.60542.59084615741_split.ms uid://evla/pdbsb/46277386 MS MS 13 273 13 6.0 GiB

No flux densities were imported.

createmms
false
overwrite
False
session
session_1
nocopy
True
output_dir
 
asis
Receiver CalAtmosphere
datacolumns
{}
bdfflags
False
process_caldevice
True
vis
/mnt/condor/execute/dir_3201977/rawdata/VLASS3.2.sb46277386.eb46352893.60542.59084615741_split.ms
save_flagonline
True
ocorr_mode
co
lazy
False
Start time
2024-08-26 18:09:07.004
End
2024-08-26 18:09:14.708
Duration
0:00:07.704
Note, WebLog generation is not included in the time.

CASA logs for stage 1