Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb45475438.eb46170878.60481.14940084491_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb45475438.eb46170878.60481.14940084491_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb45475438.eb46170878.60481.14940084491_split.ms uid://evla/pdbsb/45475438 MS MS 12 374 12 10.3 GiB

No flux densities were imported.

overwrite
False
asis
Receiver CalAtmosphere
datacolumns
{}
vis
/mnt/condor/execute/dir_1199049/rawdata/VLASS3.2.sb45475438.eb46170878.60481.14940084491_split.ms
output_dir
 
lazy
False
ocorr_mode
co
save_flagonline
True
process_caldevice
True
nocopy
True
bdfflags
False
session
session_1
createmms
false
Start time
2024-06-27 15:47:11.019
End
2024-06-27 15:47:33.724
Duration
0:00:22.705
Note, WebLog generation is not included in the time.

CASA logs for stage 1