Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb45428294.eb46169418.60478.22935620371_split.ms is missing AMPLITUDE and PHASE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb45428294.eb46169418.60478.22935620371_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb45428294.eb46169418.60478.22935620371_split.ms uid://evla/pdbsb/45428294 MS MS 10 310 10 8.4 GiB

No flux densities were imported.

output_dir
 
datacolumns
{}
ocorr_mode
co
overwrite
False
vis
/mnt/condor/execute/dir_175583/rawdata/VLASS3.2.sb45428294.eb46169418.60478.22935620371_split.ms
save_flagonline
True
session
session_1
createmms
false
asis
Receiver CalAtmosphere
lazy
False
process_caldevice
True
nocopy
True
bdfflags
False
Start time
2024-06-25 21:47:25.452
End
2024-06-25 21:47:48.378
Duration
0:00:22.925
Note, WebLog generation is not included in the time.

CASA logs for stage 1