Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb45422254.eb46193811.60499.09540233796_split.ms is missing AMPLITUDE and PHASE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb45422254.eb46193811.60499.09540233796_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb45422254.eb46193811.60499.09540233796_split.ms uid://evla/pdbsb/45422254 MS MS 13 412 13 10.5 GiB

No flux densities were imported.

output_dir
 
process_caldevice
True
session
session_1
bdfflags
False
ocorr_mode
co
overwrite
False
nocopy
True
save_flagonline
True
vis
/mnt/condor/execute/dir_338816/rawdata/VLASS3.2.sb45422254.eb46193811.60499.09540233796_split.ms
asis
Receiver CalAtmosphere
lazy
False
createmms
false
datacolumns
{}
Start time
2024-07-15 23:06:13.331
End
2024-07-15 23:06:31.873
Duration
0:00:18.541
Note, WebLog generation is not included in the time.

CASA logs for stage 1