Pipeline QA summary for this task.
Score Reason
0.00 VLASS3.2.sb46299843.eb46804205.60586.30385107639_split.ms is missing PHASE and AMPLITUDE calibration intents.
0.50 Unexpected entries were found in the HISTORY table of VLASS3.2.sb46299843.eb46804205.60586.30385107639_split.ms. This measurement set may already be processed. If hanning smooth has already been applied in previous execution, invoking hifv_hanning in a following stage means smoothing twice.

1 measurement set was registered with the pipeline. The imported data are summarized below.

Summary of Imported Measurement Sets
Measurement Set SchedBlock ID Src Type Dst Type Number Imported Size
Scans Fields Science Target
VLASS3.2.sb46299843.eb46804205.60586.30385107639_split.ms uid://evla/pdbsb/46299843 MS MS 13 415 13 12.0 GiB

No flux densities were imported.

nocopy
True
ocorr_mode
co
save_flagonline
True
session
session_1
datacolumns
{}
process_caldevice
True
lazy
False
asis
Receiver CalAtmosphere
output_dir
 
vis
/mnt/condor/execute/dir_1125492/rawdata/VLASS3.2.sb46299843.eb46804205.60586.30385107639_split.ms
createmms
false
bdfflags
False
overwrite
False
Start time
2024-11-07 21:19:55.660
End
2024-11-07 21:20:21.441
Duration
0:00:25.781
Note, WebLog generation is not included in the time.

CASA logs for stage 1